Basic Diagnoste

Basic Diagnoste
Basic Diagnoste
Product Code : 28
Product Description
Basic Diagnoste

Floor to Ceiling column  with a counterbalanced travel of the X-Ray Tube head arm.

The Basic Diagnostic System can be configured with  an output of  100kVp,100mA i.e. Basic-Diagnoste-100 & Basic- Diagnoste-300 (125kVp, 300mA).

Generator Specifications

The Basic-Diagnoste-100 is a FULLWAVE RECTIFIED system & delivers the excellent radiographic ouput of:
  • 100 mA from 40 to   80  KV for 0.4 secs. (40 mAs)
  • 80 mA from 40 to   90  KV for 0.8 secs. (64 mAs)
  • 60 mA from 40 to 100  KV for 2.0 secs. (120 mAs)
  • 40 mA from 40 to 100  KV for 5.0 secs. (200 mAs)
Input : 230 Volts, 15 Amp.
Timer : 0.04 to 5.0 secs. 23 steps.

Generator Specifications : Basic-Diagnoste-300
Generator Diagnoste- 300 delivers the excellent radiographic output as given below :

Radiography-Large Focus
  • 300 mA from 40 to   90 kV from 0.02 to  0.4 secs. (120 mAs)
  • 200 mA from 40 to 100 kV from 0.02 to 1.3 secs. (260 mAs)
  • 100 mA from 40 to 125 kV from 0.02 to 3.0 secs. (300 mAs)
Radiography-Small Focus
  • 150 mA from 40 to  90  kV from 0.02 to 2.0 secs. ( 300mAs)            
  • 100 mA from 40 to 100 kV from 0.02 to 5.0 secs. (500 mAs)
  • 50 mA from 40 to 125 kV from 0.02 to 5.0 secs. (250 mAs)
Input voltage : 440VAC, 3 phase, 30KVA
Timer : 0.02 to 5.0 Secs. 23 Steps.
Basic Diagnoste

Floor to Ceiling column  with a counterbalanced travel of the X-Ray Tube head arm.

The Basic Diagnostic System can be configured with  an output of  100kVp,100mA i.e. Basic-Diagnoste-100 & Basic- Diagnoste-300 (125kVp, 300mA).

Generator Specifications

The Basic-Diagnoste-100 is a FULLWAVE RECTIFIED system & delivers the excellent radiographic ouput of:
  • 100 mA from 40 to   80  KV for 0.4 secs. (40 mAs)
  • 80 mA from 40 to   90  KV for 0.8 secs. (64 mAs)
  • 60 mA from 40 to 100  KV for 2.0 secs. (120 mAs)
  • 40 mA from 40 to 100  KV for 5.0 secs. (200 mAs)
Input : 230 Volts, 15 Amp.
Timer : 0.04 to 5.0 secs. 23 steps.

Generator Specifications : Basic-Diagnoste-300
Generator Diagnoste- 300 delivers the excellent radiographic output as given below :

Radiography-Large Focus
  • 300 mA from 40 to   90 kV from 0.02 to  0.4 secs. (120 mAs)
  • 200 mA from 40 to 100 kV from 0.02 to 1.3 secs. (260 mAs)
  • 100 mA from 40 to 125 kV from 0.02 to 3.0 secs. (300 mAs)
Radiography-Small Focus
  • 150 mA from 40 to  90  kV from 0.02 to 2.0 secs. ( 300mAs)            
  • 100 mA from 40 to 100 kV from 0.02 to 5.0 secs. (500 mAs)
  • 50 mA from 40 to 125 kV from 0.02 to 5.0 secs. (250 mAs)
Input voltage : 440VAC, 3 phase, 30KVA
Timer : 0.02 to 5.0 Secs. 23 Steps.